Perkins · 150 kW · Diesel

Perkins diesel generator 150 kW

Perkins 150 kW diesel generator: Perkins 1106D-E70TAG3 engine, Stamford UCI274E alternator and Deep Sea DSE6120 controller, in a sound-attenuated enclosure with a 600 L tank, at 347/600 V three-phase (also available in 120/240 V single-phase, same price). $49,000 CAD before taxes. Load-bank tested for 2 hours (10 to 110%) and built for heavy-duty use, 24/7. Sold by Solution NRJ in Terrebonne.

Request a quote

Representative photo of the enclosed Perkins generator range
Representative photo supplied by Solution NRJ. The 150 kW configuration may differ; specifications are confirmed in the quotation.

Clear pricing to plan your purchase

Your configuration 150 kW

$49,000 CAD

Before taxes. Same price regardless of the voltage selected for the ordered configuration.

  • Engine heater included
  • Intelligent battery charger included
  • Preparation with oil and Prestone coolant included

Shipping is extra. Transfer switch sold separately. Installation must be specified in the quotation.

Request a quote for this model

Is this the right output for your needs?

The configuration shown is 600 V. Provide the characteristics of your electrical system and equipment to confirm voltage, phases and project compatibility.

To confirm this configuration meets your needs, assess equipment that will operate together and the power required at startup.

Your priority equipment

Identify equipment that must operate simultaneously and loads that can remain off during an outage.

Motor starting

A pump or compressor may require more power at startup than during normal operation. Provide nameplate information to assess these requirements.

Your electrical configuration

Voltage, phase count and connected loads must be considered together. Confirm the configuration before ordering.

Unsure of your power requirements? Send an equipment list and nameplate photos. We can help identify the information needed to select a model.

Specifications of the shown configuration

Fuel tank
600 litres
Dimensions (L × W)
125.98 × 44.49 in (320 × 113 cm)
Model
150 kW
Engine
Perkins 1106D-E70TAG3, 6 cylinders, turbocharged
Alternator
Stamford
Shown voltage
600 V
Power factor
0.8 (347/600 V three-phase): 150 kW / 187.5 kVA
Also available in
120/240 V single-phase, 120/208 V and 277/480 V three-phase, same price
Enclosure
Sound-attenuated enclosure
Standard controller
Deep Sea DSE6120
Stated certifications
CSA · EPA Tier 3
Stated runtime
12 hours; load and conditions to be confirmed
Warranty
1 year or 1,500 hours, whichever comes first

Plan the connection

Voltage and phases must match your installation. Equal pricing across voltages does not mean the equipment can freely switch voltage. Confirm the ordered configuration before delivery.

Fuel capacity and runtime

Fuel capacity alone does not determine runtime. Consumption varies with electrical load and operating conditions. Specify your desired duration so fuel requirements can be assessed.

Warranty: 1 year or 1,500 hours, whichever comes first. Terms are specified in the quotation.

Download the 150 kW technical sheet (PDF)

Full technical specifications

Perkins engine

Model
1106D-E70TAG3
Cylinders
6 inline, 4-stroke
Aspiration
Turbocharged, aftercooled
Displacement
7.0 L
Bore × stroke
105 × 135 mm
Compression ratio
16.8:1
Speed
1,800 rpm
Speed governor
Electronic (ECM), speed droop ≤ 1%
Cooling
Liquid
Oil (total capacity)
8.4 L
Fuel use at full load
About 38 L/h
Starting
Electric 12 V DC

Stamford alternator

Model
Stamford UCI274E, CSA approved
Excitation
Brushless, self-excited, single bearing
Frequency
60 Hz at 1,800 rpm
Power factor
0.8 (347/600 V three-phase)
Voltage regulation
± 1% (no load to full load)
Insulation class
H
Protection rating
IP23

DSE 6120 controller

Display
Voltage, frequency, engine speed, battery voltage, running hours
Alarms
Over/under speed, low oil pressure, high temperature, failure to start, charger fault, emergency stop
Automatic shutdown
Low oil pressure, high temperature, over/under speed, failure after 3 start attempts

Equipment and testing

Load bank test
2 hours, from 10% to 110% load, with protection checks; adjusted and ready to use
Exhaust
Industrial silencer and flexible hose
Included
Block heater, smart battery charger, glow plugs
Design standards
ISO 8528, NEC, CEC

Data for the configuration shown. The ordered configuration is confirmed in the quotation.

Would you like automatic operation during an outage?

An automatic transfer switch transfers power between the utility and the generator. In a compatible installation, it detects an outage and coordinates transfer to backup power and then back to the utility.

Transfer switch selection and connection must be adapted to your installation with a qualified professional. Its price is specified separately in the quotation.

Plan with your installer

  • Priority circuits and transfer equipment
  • Location, ventilation and exhaust according to manufacturer requirements
  • Access for delivery and maintenance

Your questions before choosing

Can it supply my entire building?

That depends on actual loads, simultaneous use and starting requirements. Floor area or room count alone cannot determine the required output.

How is runtime determined?

Runtime depends on fuel capacity, consumption at the operating load and operating conditions. Confirm load assumptions before relying on a stated duration.

What should I send for a quotation?

Send a priority equipment list, nameplate photos, voltage and phase count if known. Also describe automatic transfer needs and desired operating duration.

How should maintenance be planned?

For the Perkins models shown, do the first break-in service (oil and oil filter) at 60 hours, then plan oil changes every 250 hours and fuel filter replacement every 500 hours. The engine manual also specifies calendar intervals, other tasks and special conditions.

Tell us about the equipment you need to power

Tell us what must stay running during an outage. With information about your installation, we can prepare a tailored quotation and specify the proposed configuration.

Request a quote for this model

Solution NRJ
438-350-6979
ventes@solutionnrj.com

Return policy

We do not accept returns.

See also

Our projects: generators delivered and installed, and workshop work, in photos.