Perkins · 15 kW · Diesel

15 kW Perkins diesel generator

Perkins 15 kW diesel generator (15,000 W): Perkins 403D-15G engine, Stamford PI144D alternator and Deep Sea DSE6120 controller, in a sound-attenuated enclosure with a 200 L tank. $16,000 CAD before taxes. Load-bank tested for 2 hours (10 to 110%) and built for heavy-duty use, 24/7. Sold by Solution NRJ in Terrebonne.

Request a quote

Grey enclosed diesel generator with doors open showing the engine
Model photo provided by Solution NRJ. Your selected configuration will be specified in your quote.

Clear pricing to plan your purchase

Your configuration 15 kW

$16,000 CAD

Before taxes. Same price regardless of the voltage selected for the ordered configuration.

  • Engine heater included
  • Intelligent battery charger included
  • Preparation with oil and Prestone coolant included
  • Glow plugs

Shipping is extra. Transfer switch sold separately. Installation must be specified in the quotation.

Request a quote for this model

Get the price and spec sheet

The Perkins 15 kW spec sheet (PDF) and price are emailed to you, usually within minutes.

This information is used to respond to your enquiry. It does not subscribe you to a mailing list. Read our privacy policy.

Is this the right output for your needs?

Start with essential circuits: lighting, refrigeration and priority equipment. Electric heating and pump starting can substantially change the power required.

To confirm this configuration meets your needs, assess equipment that will operate together and the power required at startup.

Your priority equipment

Identify equipment that must operate simultaneously and loads that can remain off during an outage.

Motor starting

A pump or compressor may require more power at startup than during normal operation. Provide nameplate information to assess these requirements.

Your electrical configuration

Voltage, phase count and connected loads must be considered together. Confirm the configuration before ordering.

Unsure of your power requirements? Send an equipment list and nameplate photos. We can help identify the information needed to select a model.

Specifications of the shown configuration

Advertised output
15 kW
Fuel
Diesel
Engine
Perkins 403D-15
Alternator
Stamford
Frequency
60 Hz
Power factor
1.0 (120/240 V single-phase): 15 kW / 15 kVA
Also available in
120/208 V, 277/480 V and 347/600 V three-phase, same price
Standard controller
DSE 6120
Cylinders
3
Shown voltage
120/240 V
Fuel tank
200 litres
Estimated runtime
About 60 hours at 75% load; depending on load and conditions
Certifications
CSA · EPA Tier 3

Plan the connection

Voltage and phases must match your installation. Equal pricing across voltages does not mean the equipment can freely switch voltage. Confirm the ordered configuration before delivery.

Fuel capacity and runtime

200-litre tank; about 60 hours of runtime at 75% load (fuel use of about 3.3 L/h), depending on load and conditions. This duration is not a full-load guarantee.

Fuel capacity alone does not determine runtime. Consumption varies with electrical load and operating conditions. Specify your desired duration so fuel requirements can be assessed.

Warranty: 1 year or 1,500 hours, whichever comes first. Terms are specified in the quotation.

Download the 15 kW technical sheet (PDF)

Review the technical document alongside the proposed generator specifications. An engine datasheet does not replace the electrical specifications of the complete generator set.

Full technical specifications

Perkins engine

Model
403D-15G
Cylinders
3 inline, 4-stroke
Aspiration
Naturally aspirated
Displacement
1.5 L (1,496 cc)
Bore × stroke
84 × 90 mm
Compression ratio
22.5:1
Speed
1,800 rpm
Speed governor
Mechanical, speed droop ≤ 1%
Cooling
Liquid
Oil (total capacity)
6.0 L
Coolant
6 L
Fuel use at 75% load
About 3.3 L/h
Starting
Electric 12 V DC

Stamford alternator

Model
Stamford PI144D, CSA approved
Excitation
Brushless
Frequency
60 Hz at 1,800 rpm
Power factor
1.0 (120/240 V single-phase)
Voltage regulation
± 0.5% (no load to full load)
Insulation class
H
Protection rating
IP23

DSE 6120 controller

Display
Voltage, frequency, engine speed, battery voltage, running hours
Alarms
Over/under speed, low oil pressure, high temperature, failure to start, charger fault, emergency stop
Automatic shutdown
Low oil pressure, high temperature, over/under speed, failure after 3 start attempts

Equipment and testing

Load bank test
2 hours, from 10% to 110% load, with protection checks; adjusted and ready to use
Exhaust
Industrial silencer and flexible hose
Included
Block heater, smart battery charger, glow plugs
Design standards
ISO 8528, NEC, CEC

Data for the configuration shown. The ordered configuration is confirmed in the quotation.

Would you like automatic operation during an outage?

An automatic transfer switch transfers power between the utility and the generator. In a compatible installation, it detects an outage and coordinates transfer to backup power and then back to the utility.

Transfer switch selection and connection must be adapted to your installation with a qualified professional. Its price is specified separately in the quotation.

Plan with your installer

  • Priority circuits and transfer equipment
  • Location, ventilation and exhaust according to manufacturer requirements
  • Access for delivery and maintenance

Your questions before choosing

Can it supply my entire building?

That depends on actual loads, simultaneous use and starting requirements. Floor area or room count alone cannot determine the required output.

How is runtime determined?

Runtime depends on fuel capacity, consumption at the operating load and operating conditions. Confirm load assumptions before relying on a stated duration.

What should I send for a quotation?

Send a priority equipment list, nameplate photos, voltage and phase count if known. Also describe automatic transfer needs and desired operating duration.

How should maintenance be planned?

For the Perkins models shown, do the first break-in service (oil and oil filter) at 60 hours, then plan oil changes every 250 hours and fuel filter replacement every 500 hours. The engine manual also specifies calendar intervals, other tasks and special conditions.

Tell us about the equipment you need to power

Tell us what must stay running during an outage. With information about your installation, we can prepare a tailored quotation and specify the proposed configuration.

Request a quote for this model

Solution NRJ
438-350-6979
ventes@solutionnrj.com

Return policy

We do not accept returns.